Zaytsev V.V., Mamontov O.V., Kamshilin A.A. Assessment of cutaneous blood flow in lower extremities by imaging photoplethysmography method. Scientific and Technical Journal of Information Technologies, Mechanics and Optics, 2019, vol. 19, no. 6,  pp. 994–1003 (in Russian). doi: 10.17586/2226-1494-2019-19-6-994-1003


Abstract
Subject of Research. The paper presents effective application of the novel imaging photoplethysmography method for receiving data on reaction of peripheral blood flow in lower extremities on venous occlusion. Method. Four digital cameras were used to record synchronously videos of all-around view of the subject’s lower limb illuminated by green light (525 nm). For blood flow reactivity assessment, four consecutive venous occlusions were applied for 10 s by rapid increase of the pressure up to 60 mm Hg in an occlusal cuff situated at the lower third of the thigh followed by 20-second recovery period. Two techniques were used and compared for processing of experimental data: by averaging of camera matrix pixel values in arbitrary chosen regions of interest and by component analysis of camera video signals. It was found out that the technique of the pixel value averaging provides a more reliable quantitative assessment of peripheral blood flow parameters in lower extremities. The data processing algorithm was optimized. Main Results. The study involved 16 healthy volunteers. Data analysis has shown that dynamics of changes in the intensity of light interacting with the lower leg during occlusion was successfully obtained in all subjects. The shape of the optically measured response on venous occlusion was found out to be the same as the curves of classical air plethysmography applied to evaluation of musculocutaneous blood flow in the forearm. Practical Relevance. Taking into account the simplicity and contactless nature of the study, the imaging photoplethysmography method can be widely introduced into clinical practice for research of the functional state of the lower extremity vessels in a wide range of diseases.

Keywords: photoplethysmography, peripheral blood flow, venous occlusion, plethysmography

Acknowledgements. The research was supported by the Russian Science Foundation (Grant N 15-15-20012).

References
 
  1. Wilkinson I.B., Webb D.J. Venous occlusion plethysmography in cardiovascular research: methodology and clinical applications. British Journal of Clinical Pharmacology, 2001, vol. 52, no. 6, pp. 631–646. doi: 10.1046/j.0306-5251.2001.01495.x
  2. Alnaeb M.E., Alobaid N., Seifalian A.M., Mikhailidis D.P., Hamilton G. Optical Techniques in the Assessment of Peripheral Arterial Disease. Current Vascular Pharmacology, 2007, vol. 5, no. 1, pp. 53–59. doi: 10.2174/157016107779317242
  3. Kamshilin A.A., Miridonov S., Teplov V., Saarenheimo R., Nippolainen E. Photoplethysmographic imaging of high spatial resolution. Biomedical Optics Express, 2011, vol. 2, no. 4, pp. 996–1006. doi: 10.1364/BOE.2.000996
  4. Fallow B.A., Tarumi T., Tanaka H. Influence of skin type and wavelength on light wave reflectance. Journal of Clinical Monitoring and Computing, 2013, vol. 27, no. 3, pp. 313–317. doi: 10.1007/s10877-013-9436-7
  5. Trumpp A., Bauer P.L., Rasche S., Malberg H., Zaunseder S. The value of polarization in camera-based photoplethysmography. Biomedical Optics Express, 2017, vol. 8, no. 6, pp. 2822. doi: 10.1364/BOE.8.002822
  6. Kamshilin A.A., Zaytsev V.V., Mamontov O.V. Novel contactless approach for assessment of venous occlusion plethysmography by video recordings at the green illumination. Scientific Reports, 2017, vol. 7, no. 1, pp. 464. doi: 10.1038/s41598-017-00552-7
  7. Zaytsev V.V., Miridonov S.V., Mamontov O.V., Kamshilin A.A. Contactless monitoring of the blood-flow changes in upper limbs. Biomedical Optics Express, 2018, vol. 9, no. 11, pp. 5387–5399. doi: 10.1364/boe.9.005387
  8. Kamshilin A.A., Nippolainen E., Sidorov I.S., Vasilev P.V., Erofeev N.P., Podolian N.P., Romashko R.V. A new look at the essence of the imaging photoplethysmography. Scientific Reports, 2015, vol. 5, pp. 10494. doi: 10.1038/srep10494
  9. Jolliffe I.T., Cadima J. Principal component analysis: a review and recent developments. Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences, 2016, vol. 374, no. 2065, pp. 20150202. doi: 10.1098/rsta.2015.0202
  10. Allen J. Photoplethysmography and its application in clinical physiological measurement. Physiological Measurement, 2007, vol. 28, no. 3, pp. R1–R39. doi: 10.1088/0967-3334/28/3/R01
  11. Strain W.D., Chaturvedi N., Hughes A., Nihoyannopoulos P., Bulpitt C.J., Rajkumar C., Shore A.C. Associations between cardiac target organ damage and microvascular dysfunction: The role of blood pressure. Journal of Hypertension, 2010, vol. 28, no. 5, pp. 952–958. doi: 10.1097/HJH.0b013e328336ad6c
  12. Tibirica E., Souza E.G., De Lorenzo A., Oliveira G.M.M. Reduced systemic microvascular density and reactivity in individuals with early onset coronary artery disease. Microvascular Research, 2015, vol. 97, pp. 105–108. doi: 10.1016/j.mvr.2014.10.004


Creative Commons License

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License
Copyright 2001-2024 ©
Scientific and Technical Journal
of Information Technologies, Mechanics and Optics.
All rights reserved.

Яндекс.Метрика